Australian Daily Wind Power Generation Data – Friday 19 February 2021

Posted on Sat 02/20/2021 by

0


By Anton Lang ~

This Post details the daily wind power generation data for the AEMO coverage area in Australia. For the background information, refer to the Introductory Post at this link.

Each image is shown here at a smaller size to fit on the page alongside the data for that day. If you click on each image, it will open on a new page and at a larger size so you can better see the detail.

Note also that on some days, there will be a scale change for the main wind power image, and that even though images may look similar in shape for the power generation black line on the graph when compared to other days, that scale (the total power shown on the left hand vertical axis) has been changed to show the graph at a larger size to better fit the image for that graph.

Friday 19 February 2021

Total Wind Power Generation

This image shows the total power generated across the whole day by every wind plant in this vast AEMO coverage area for Australia.

The total Nameplate for all these wind plants changes as each new wind plant comes on line delivering power to the grid. That current Nameplate is 8132MW, and this is from the current total of 67 wind plants.

Note that the shape of this wind power load curve does not follow the shape of the main load curve for total power generation, and that is seen in the image below, the solid black line across the top of the image for that graph. Wind power generates its power only when the wind is blowing, hence it does not follow the actual power generation Load Curve, which is also the the exact same shaped curve as for actual power consumption.

For this data, I have added the times for the daily minimum, and the daily maximum, to show how they do not correlate with the actual times of minimum power consumption (around 4AM each day) and maximum power consumption, the evening Peak. (at around 6.40PM in Winter and earlier during the Summer Months.)

Daily Minimum – 1732MW (3.55PM)

Daily Maximum – 4916MW (4.50AM)

Average Wind Generation – 3263MW

Total Generated Power – 78.31GWH

Percentage Supplied By Wind Power At The Low Point For The Day – 5.7%

Percentage Supplied By Wind Power At Peak Power For The Day – 1738MW of 30450MW – 3.50PM – 5.70%

Average Percentage Of Overall Total Power Generation – 12.8%

Daily Operational Capacity Factor – 40.13%

Wind Power Generation Versus Total Power Generation

This image shows the total power generated from all the wind plants in this AEMO coverage area, and compares it to the overall total generated power from every source of power generation, which is the black line at the top of the graph. Wind power is the green coloured area, along the bottom of this graph.

While the green colour in this image looks to be a different shape to the graph above, keep in mind here that the scale is completely different, and that green coloured Wind total is the same as for the image shown above, only with the scale changed so it can fit onto the graph.

Notes

  1. Finding Wind Power Average – On the graph, there are 25 hourly time points, starting with midnight and finishing with midnight. I have added the total at each of those hourly time points together, and divided the resultant total by 25 to give an average in MegaWatts. (MW)
  2. For total power in GWH, multiply the average daily power by 24, and then divide by 1000.
  3. For the Capacity Factor, that is calculated by dividing the average wind generation by the current Nameplate and then multiplying that by 100 to give a percentage.

Comments For This Day

On this day, wind generation was still very high, but lower than it was on the day before. That average of 3263ME gave wind generation a daily operational Capacity Factor of 40.1%, and again, note the irony that on a very good day for wind generation it is still only operating at 40% of its total Nameplate of 8123MW. Again you can see that wind was low as overall power consumption was high, and again, the low for wind generation corresponded exactly with the high for overall power consumption, when at that time, wind was only delivering 5.7% of all the generated power. Note the difference between the high for the day and the low, and that was almost 3200MW a huge difference and that’s a gap of almost 67%. Also, look again at that high for the day, and that’s a very large 4916MW and at that time, that meant that wind was operating at a tick over 60%, getting up towards the highest that wind generation has ever been, even though that time it was highest, there was less wind plants in operation. Also note that the high of that 4916MW is just for one five minute point in time. No matter how much you can try to ‘beat up’ that wind power might be good, the truth is that while it looks like that some of the time, those times are so few and far between.

*****

Anton Lang uses the screen name of TonyfromOz, and he writes at this site, PA Pundits International on topics related to electrical power generation, from all sources, concentrating mainly on Renewable Power, and how the two most favoured methods of renewable power generation, Wind Power and all versions of Solar Power, fail comprehensively to deliver levels of power required to replace traditional power generation. His Bio is at this link.

OzWindPowerGenerationTFO